Main SP Tables-2
SM 5-71 D086/D087
System
Maintenance
2311 [Non Image Area: Bias]
001 Image Transfer *ENG
Adjusts the bias of the image transfer belt
between images. This value is added to the
value of the image transfer belt bias.
[10 to 250 / 100 / 5 %/step]
002 Paper Transfer *ENG
Adjusts the bias of the paper transfer roller
between images.
[0 to 2000 / 500 / 1 V/step]
2326 [Transfer Roller CL: Bias] Transfer Roller Cleaning: Bias Adjustment
001
Positive *ENG
[0 to 2100 / 500 / 100 V /step]
Adjusts the positive voltage of the paper transfer roller for cleaning the paper
transfer roller.
002
Negative *ENG
[10 to 400 / 100 / 10 %/step]
Adjusts the negative current of the paper transfer roller for cleaning the paper
transfer roller.
003
Positive *ENG
[0 to 2100 / 2000 / 100 V/step]
Adjusts the negative current limit of the paper transfer roller for cleaning the
paper transfer roller.
004 Negative *ENG
[10 to 400 / 100 / 10 %/step]