HIGH DATA RATE RECEIVER
HDR-4G+ USER’S MANUAL
Ref. DTU 100782
Is.Rev 3.5
Date: June 1, 2021
© Safran Data Systems – IMP000074 e14r1
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Data output 3.4.13.4
Data at the output of each DPU can be recorded in specific directories of the internal hard disk named
“T” or/and output at the ECL connectors as a single data stream with its clock.
The recording directories architecture is the following:
The report files are recorded in:
T:\DiskController_1_00\Report_TMA for DPU A
T:\DiskController_1_00\Report_TMB for DPU B
T:\DiskController_1_00\Report_TMC for DPU C
T:\DiskController_1_00\Report_TMD for DPU D
T:\DiskController_1_00\Report_TME for DPU E
T:\DiskController_1_00\Report_TMF for DPU F
T:\DiskController_1_00\Report_TMG for DPU G
T:\DiskController_1_00\Report_TMH for DPU H
The data files are recorded in:
T:\DiskController_1_01\.... for DPU A
T:\DiskController_1_03\.... for DPU C
T:\DiskController_1_05\.... for DPU E
T:\DiskController_1_07\.... for DPU G
T:\DiskController_1_02\.... for DPU B
T:\DiskController_1_04\.... for DPU D
T:\DiskController_1_06\.... for DPU F
T:\DiskController_1_08\.... for DPU H
If the CCSDS Virtual Channel sorting is disabled (TFP window), the data files are recorded inside the
sub-directories CV_XX of each directory.
If the CCSDS Virtual Channel sorting is enabled, the data files are recorded inside the specific sub-
directories: CV_NN with NN = 00 to 63 being the Virtual Channel ID number.
Multi-DPU outputs on ECL connectors are described in chapter 2.