HIGH DATA RATE RECEIVER
HDR-4G+ USER’S MANUAL
Ref. DTU 100782
Is.Rev 3.5
Date: June 1, 2021
© Safran Data Systems – IMP000074 e14r1
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
Data Storage 1.6.4
Associated Hardware:
The Data storage system can be according the following configuration:
Raid 0 with 4 Disk
Raid 6 with 12 Disk
Disk configuration are SSD or HDD
Disk capacity are 1 Terrabytes or 2 Terrabytes
Data storage total capacity can be from: 4 Terrabytes to 20 Terrabytes
Read/Write Performance:
Raid 6 with 12 disk >10Gbit aggregate R/W
Raid 0 with 4 disk >4 Gbit aggregate R/W
File Associated Process for FTP access:
Files architecture and construction Destination directories programmable
Destination files names programmable
Decommutation, filtering and sorting up to 5 fields in CADU
Up to 64 destination files
File size defined by the number of frames from 20 Mbytes to 4
Gbytes
Data recovery FTP Read and Delete commands supported
Disk space management Warning level programmable
Alarm level for auto-erase programmable
Delete of the oldest files (date programmable)
Auto tests Auto test of directories and files