HIGH DATA RATE RECEIVER
HDR-4G+ USER’S MANUAL
Ref. DTU 100782
Is.Rev 3.5
Date: June 1, 2021
© Safran Data Systems IMP000074 e14r1
Page 298
Control 4.5.5.3.1
Unless otherwise specified, parameters in this window are described in DPU.
OPERATING MODE
BER measurement mode (simulated data for BER analyzis):
Off BER measurement stopped
File Simulated data from a file on the
PseudoDxx Pseudo random data, using from PN generator xx
(where xx = 7, 10, 11, 15, 23 or 31)
INVERSE
Inverse (Enable) or not (Disable) the data used for BER computation
TESTED DATA
User Data Compute the BER only on the User data of the frames
(excluded added check symbols)
Whole Data Compute the BER on all the received data of the frames
Custom Pattern Compute the BER on a user-defined portion of the frame.
The custom BER pattern is defined inside an ASCII file stored on the hard
drive.
FILE NUMBER
File number for BER in file mode: enter any value from 1 to N.
BER PATTERN
NUMBER
File number for user-defined BER pattern in Custom Pattern mode: enter any
value from 1 to N
BER COUNTER
Total number of bits to process for BER measurement in Pseudo mode
Resolution step: 65536 bits. In File Mode, Infinite accumulation.
Monitoring 4.5.5.3.2
Unless otherwise specified, status & alarms in this window are described in DPU.
BER
Computed Bit Error Rate
NUMBER OF ERROR
Cumulated number of errors