HIGH DATA RATE RECEIVER
HDR-4G+ USER’S MANUAL
Ref. DTU 100782
Is.Rev 3.5
Date: June 1, 2021
© Safran Data Systems IMP000074 e14r1
Page 265
Flow Id. (Hex) 4.5.4.1.1.2
SPECTRUM
Identification of the Spectrum data flow. This value is reported in all TCP-IP
messages transmitted over the Spectrum Analysis Data port (SPA). Enter any
hexadecimal value from 0 to FFFFFFFF
VECTOR
Identification of the Vector Analysis data flow. This value is reported in all
TCP-IP messages transmitted over the Vector Analysis Data port (VEC). Enter
any hexadecimal value from 0 to FFFFFFFF
Matched Filter 4.5.4.1.1.3
FILTER
Bit synchronizer filter. Satellite-dependent parameter:
Integral
Integral & Dump
Raised Raised Cosine (See Roll-off)
Root Raised Root Raised Cosine (See Roll-off)
Custom Custom filters (See Fir Cust. Nb)
GMSK GMSK filters (See BT)
SOQPSK SOQPSK filters (See SOQPSK Norm)
ROLL-OFF
Filter roll-off factor: enter any value from 0.1 to 1.0.
FIR CUSTOM NB
FIR custom Number: enter any value from 1 to 1000.
BT FACTOR
GMSK Filter BT factor: 0.25 or 0.5.
SOQPSK NORM
MIL MIL standard filter
TG IRIG standard filter (IRIG standard 106-04)
A CCSDS A-type filter (CCSDS 413.0-G-1)
B CCSDS B-type filter
ASYM
Select asymmetrical FIR coefficients, else symmetrical FIR coefficients are
applied.
COMP
Select complex FIR coefficients, else real FIR coefficients are applied
(dependent of the other FIR characteristics selections).
ODD
Select odd FIR coefficients, else even FIR coefficients are applied.
4*SR
Select the sample rate of the FIR filter as 4 time the symbol rate, else 2 time the
symbol rate is applied.
DEAF
Select the DEAF mode (Digital Equalization Automatic Filter).
CMA / LMS
Select the algorithm of the DEAF function. It is recommended to use the LMS
algorithm for the reception of frequency non symmetrical signals.
FAST
Select fast DEAF computation.
XDEAF
Select the automatic cross-polarization compensation function.