HIGH DATA RATE RECEIVER
HDR-4G+ USER’S MANUAL
Ref. DTU 100782
Is.Rev 3.5
Date: June 1, 2021
© Safran Data Systems – IMP000074 e14r1
This document is the property of Safran Data Systems.
It cannot be duplicated or distributed without expressed written consent.
CORTEX HDR System Parameters in Registry 4.2.9
CORTEX Station 4.2.9.1
Menus Description 4.2.9.1.1
Access path to the Menu Description file (menu.txt).
Registry path: HKEY_LOCAL_MACHINE/SOFTWARE/In-Snec/Cortex Station/Remote Control
Keyword: MenuDescription
Default setting: "C:\\Program Files\\IN-SNEC\\crtxNt\\Menus\\menu.txt”
Last Used Menu 4.2.9.1.2
This status indicates what was the working menu before shutting down the machine
Registry path: HKEY_LOCAL_MACHINE/SOFTWARE/In-Snec/Cortex Station/Remote Control
Keyword: LastConfiguration
RAC Port Number 4.2.9.1.3
Allows changing the RAC port number:
Registry path: HKEY_LOCAL_MACHINE/SOFTWARE/In-Snec/Cortex Station/Remote Control
Keyword: PortCntx
Default setting: 3003
Demodulation Unit 4.2.9.2
Output Clock ON/OFF 4.2.9.2.1
Enabling or disabling the data clock from the Bit Synchronizer:
Registry path: HKEY_LOCAL_MACHINE/SOFTWARE/InSnec/CrtxHdr/SetDefault/Preferences
/Dmu#n
Keyword: ClkOut
Enter 0 for permanent clock
Enter 1 for disabling the clock signal when the Bit Synchronizer is unlocked.
Enter 2 for limiting the clock signal frequency deviation to 0.1% of the programmed bit rate when the Bit
Synchronizer is unlocked, and outputting the effective bit rate when the Bit Synchronizer is locked.
Enter 3 for clock setting accuracy better than 1 ppm when the Bit Synchronizer is unlocked and
outputting the effective bit rate when the Bit Synchronizer is locked.
Enter 4 for clock disabling during frequency acquisition.
Default setting: 0 (clock always present)