HIGH DATA RATE RECEIVER
HDR-4G+ USER’S MANUAL
Ref. DTU 100782
Is.Rev 3.5
Date: June 1, 2021
© Safran Data Systems IMP000074 e14r1
Page 23
CE MARKING
Markings are placed at the rear of the unit, regarding the power ratings and “CE” compliance:
The “CE” symbol on the PC chassis indicates that it is in compliance with the Electromagnetic Compatibility directive
and the low Voltage directive.
This equipment is a: Group 1 Class A product
The following technical standards must be met:
EN 55022
Limits and methods of measurement of radio interference characteristics of
information technology equipment
EN 61000-3-2
Limits for harmonic currents emissions’’
EN 61000-4-2
Limits and methods of measurement - Section 2: electrostatic discharge immunity
test
EN 61000-4-3
Limits and methods of measurement Section 3: Radiated radio-frequency,
electromagnetic field immunity test
EN 61000-4-4
Limits and methods of measurement - Section 4: Electrical fast transient / burst
immunity test
EN 61000-4-5
Limits and methods of measurement - Section 5: Surge immunity test
EN 61000-4-6
Limits and methods of measurement - Section 6: immunity to conducted
disturbances, induced by radio-frequency fields
EN 61000-4-8
Limits and methods of measurement - Section 8: Power frequency magnetic field
immunity test
EN 61000-4-11
Limits and methods of measurement - Section 11: Voltage dips, short interruptions
as voltage variations immunity tests
The unit also complies with all staff safety standards and decrees, in particular:
Decree of 14.11.1989 and additions: Regulation of worker protection,
Directive 2006/95/EC.
In accordance with European Community directives, a “Declaration of Conformity” has been made and is available by
contacting technical support.
Recommendation concerning the cabling:
“CE” certification has been carried out with 3-meter interconnecting cables with remote equipment.
Safran Data Systems recommends the use of high quality interconnecting cables type. The high quality recommended
user interconnecting cables are “shield twisted pair” or “coaxial cable” industrial type with cable shield. The cable shield
will provide the necessary mechanical protection.
Not using this high quality designed cable could result in unexpected intersystem/extrasystem electromagnetic emission
and susceptibility.