Simulating machining
5.10 Displaying simulation alarms
Turning
196 Operating Manual, 03/2013, 6FC5398-8CP40-3BA1
5.10 Displaying simulation alarms
Alarms might occur during simulation. If an alarm occurs during a simulation run, a window
opens in the operating window to display it.
The alarm overview contains the following information:
Date and time
Deletion criterion
Specifies with which softkey the alarm is acknowledged
Alarm number
Alarm text
Precondition
Simulation is running and an alarm is active.
Procedure
1. Press the "Program control" and "Alarm" softkeys.
The "Simulation Alarms" window is opened and a list of all pending
alarms is displayed.
Press the "Acknowledge alarm" softkey to reset the simulation alarms
indicated by the Reset or Cancel symbol.
The simulation can be continued.
- OR -
Press the "Simulation Power On" softkey to reset a simulation alarm
indicated by the Power On symbol.

Table of Contents