Ctrl-Energy
19.2 Displaying energy consumption
Turning
760 Operating Manual, 03/2013, 6FC5398-8CP40-3BA1
19.2 Displaying energy consumption
You have the option of displaying the actual energy consumption values of the individual
axes and the total energy consumption.
Display Meaning
Manual
• No input
• Entering and displaying a fixed value
• Displaying a value from a data source
Sentron PAC Displaying an actual value measured by a SENTRON PAC device.
Total, drives Display of the total of all measured drive values.
Total, machine Addition of the values of all axes as well as a fixed value and Sentron
PAC.
The display in the table depends on the configuration.
References
Information on the configuration is provided in the following reference:
System Manual "Ctrl-Energy", SINUMERIK 840D sl / 828D
Procedure
1. Select the "Parameter" operating area and press the "Ctrl-Energy" softkey.
- OR -
+ Press the <Ctrl> + <E> keys.
(
2. Press the "Energy analysis" softkey.
The "SINUMERIK Ctrl-Energy Analysis" window opens.
You obtain a display of the actual active power for all of the axes.