Managing programs 
  12.12 Set up drives 
Turning 
Operating Manual, 03/2013, 6FC5398-8CP40-3BA1 
661 
 
...  
 
3.  Press the ">>" and "Properties" softkeys. 
The "Properties from ..." window appears. 
  4.  Enter any necessary changes. 
Note: You can save changes via the user interface in the NC memory. 
 
5.  Press the "OK" softkey to save the changes. 
12.12  Set up drives 
12.12.1  Overview 
 Up to eight connections to so-called logical drives (data carriers) can be configured. These 
drives can be accessed in the "Program manager" and "Startup" operating areas.  
The following logical drives can be set up: 
●  USB interface 
●  CompactFlash card of the NCU, only for SINUMERIK Operate in the NCU 
●  Network drives 
●  Local hard disk of the PCU, only for SINUMERIK Operate on the PCU 
 
 
Software option 
In order to use the CompactFlash card as data carrier, you require the "Additional 
HMI user memory on CF card of the NCU" option (not for SINUMERIK Operate on 
PCU or PC). 
 
 
 
Note 
The USB interfaces of the NCU are not available for SINUMERIK Operate and therefore 
cannot be configured.