Managing programs 
  12.17 RS-232-C 
Turning 
Operating Manual, 03/2013, 6FC5398-8CP40-3BA1 
683 
V24 setting  Meaning 
End of data transfer (hex)  Only for punched tape format 
Stop with end of data transfer character 
The default setting for the end of data transfer character is (HEX) 1A 
Time monitoring (sec)  Time monitoring 
For data transfer problems or at the end of data transfer (without end 
of data transfer character) data transfer is interrupted after the 
specified number of seconds.  
The time monitoring is controlled by a time generator (clock) that is 
started with the first character and is reset with each transferred 
character. 
The time monitoring can be set (seconds). 
Procedure 
 
 
1.  Select the "Program Manager" operating area. 
 
 
 
 
 
2.  Press the "NC" or "Local drive" softkey. 
 
 
3.  Press the ">>" and "Archive" softkeys. 
 
 
 
4.  Select the "V24 settings" softkey. 
The "Interface: V24" window is opened. 
  5.  The interface settings are displayed. 
 
6.  Press the "Details" softkey if you wish to view and process 
additional settings for the interface.