272 Dolby
®
IMS2000 Installation and User’s Manual
IMS.OM.004730.DRM Issue 3
17.6.1 Permanently Setting the Network Configuration
It is possible to permanently set the IP only via the USB. The files to put on the USB are
the same as presented but in the directory
/doremi/update/network instead of
/doremi/tmp/network.
17.7 Generating a Detailed Report
17.7.1 Generating a Report via USB
To generate a report using a USB key:
1. Create a directory
doremi at the root of the USB key. This may have been previously
created.
2. Create a directory report inside the /
doremi directory.
3. Safely remove the USB drive, and plug it into the IMS2000.
4. Wait two minutes without any USB activity. (Watch your USB key LED.)
5. Reboot the IMS2000.
The report will be in the USB key folder
/doremi/report.
17.7.2 Generating a Report via Command Line
To generate a report via command line:
1. Log in via SSH.
2.
Type: sh /doremi/sbin/report.sh.
This will generate a report and place it in the
/doremi/tmp directory.
3. Log in using an FTP client with the following criteria:
Host: IP
User name:
root
Password: ask you administrator
Port: 22