Chapter 3 ’Web User Graphical Interface’ — Workflow Library
282 Electra VS
-
Version 05.10
User Manual - Rev. A
Figure 3-252. Segment and chunk for HLS
ESAM conditioning
: if set to
true
, the Event Signaling and
Management (ESAM) is enabled. The chunker will insert
chunk/segment start for the timestamps corresponding to splice in or
out points that the Placement Opportunity Information System (POIS)
server has validated. The incoming SCTE 35 sections splice_insert and
time_signal are considered. The SCTE 35 output produces the
SCTE 35 sections following the POIS indications. The following
parameters shall be configured.
Figure 3-253. Chunker parameters (ESAM conditioning true)
Acquisition Point Identity
: A required string, typically a
system-wide unique string, identifying the Electra VS at a
specific site on a specific channel/network feed.
POIS URL
: the URL to reach the POIS server.
LAN to POIS or POIS IP address
: this parameter can be a
LAN or an IP address. If this is a LAN, then the IP address of the
POIS server will be retrieved from the URL (using DNS if the
name of the POIS server is given). The LAN shall be the one that
will be used to send data to the POIS server.
Timeout for POIS response
: the maximum allowed time for
the response of the POIS to a request. After this timeout any
response will be discarded. In this case, the original SCTE 35
incoming section is also discarded.
segment used for HLS
chunk
(2 seconds about)