4.25 Storm Control
4.25.1 Storm-control unit
Command:
storm-control unit (bps | pps)
Parameter:
Storm control rate calculates by octet-based
Storm control rate calculates by packet-based
Default:
Default storm control unit is bps.
Mode:
Global Configuration
Usage Guide:
Storm control mechanism will try to calculate ingress packets is exceed configured rate or not and do corresponding
action. This command allows you to change the unit of calculating method
Example:
This example shows how to configure storm control rate unit as pps.
Switch(config)# storm-control unit pps
This example shows how to show storm control global configuration
Switch# show storm-control
Storm control preamble and IFG: Excluded
Storm control unit: pps
..........................................
4.25.2 storm-control ifg