System SP1-xxx
SM Appendix 3-23 D086/D087
Appendix:
SP Mode
Tables
1124
[CPM Down Setting]
Specifies the settings for the CPM down mode.
001
Low:Down Temp. *ENG
[-50 to 0 / -20 / 1 deg/step]
Specifies the CPM down threshold temperature for the low temperature
condition. If the fusing temperature decreases -20°C (adjustable) below the
target temperature, the machine enters the CPM down mode.
002
Low:Up Temp. *ENG
[-50 to 0 / -15 / 1 deg/step]
Specifies the CPM up threshold temperature for the low temperature condition.
If the fusing temperature increases -15°C (adjustable) below the target
temperature, the machine enters the CPM up mode.
003
Low :1st CPM *ENG
[10 to 100 / 80 / 5 %/step]
Specifies the 1st CPM down ration against the normal CPM in the low
temperature condition.
004
Low :2nd CPM *ENG
[10 to 100 / 65 / 5 %/step]
Specifies the 2nd CPM down ration against the normal CPM in the low
temperature condition.
005
Low :3rd CPM *ENG
[10 to 100 / 50 / 5 %/step]
Specifies the 3rd CPM down ration against the normal CPM in the low
temperature condition.
006
High :1st CPM *ENG
[10 to 100 / 75 / 5 %/step]
Specifies the 1st CPM down ration against the normal CPM in the high
temperature condition.
007
High:2nd CPM *ENG
[10 to 100 / 50 / 5 %/step]
Specifies the 3rd CPM down ration against the normal CPM in the high
temperature condition.
008
High:3rd CPM *ENG
[10 to 100 / 25 / 5 %/step]
Specifies the 1st CPM down ration against the normal CPM in the high
temperature condition.