System SP1-xxx
D086/D087 3-22 SM Appendix
Specifies the target temperature of the pressure roller center area after the
fusing temperature has reached the reload temperature.
005
End Uniform Start
Temp.:B4
*ENG
[0 to 250 / 200 / 1 deg/step]
Specifies the target temperature of the pressure roller end arear after the B4
paper feeding has finished.
006
End Uniform Start
Temp.:A4
*ENG
[0 to 250 / 185 / 1 deg/step]
Specifies the target temperature of the pressure roller end arear after the A4
paper feeding has finished.
007
End Uniform Start
Temp.:A5
*ENG
[0 to 250 / 170 / 1 deg/step]
Specifies the target temperature of the pressure roller end arear after the A5
paper feeding has finished.
008
Overshoot Prevent Temp. *ENG
[0 to 250 / 220 / 1 deg/step]
Specifies the temperature of the heating roller for the overshoot prevention.
009
Overshoot Prevent Time *ENG
[0 to 100 / 10 / 1 sec/step]
Specifies the interval of the fusing unit rotation for the overshoot prevention.
1122
[Standby Rotation Setting] DFU
001
Rotation Interval *ENG
[0 to 240 / 60 / 1 min/step]
Specifies the rotation interval of the fusing unit in the stand-by mode.
002
Rotation Time *ENG
[0 to 60 / 0.7 / 0.1 sec/step]
Specifies the rotation time of the fusing unit in the stand-by mode.