System SP1-xxx
SM Appendix 3-31 D086/D087
Appendix:
SP Mode
Tables
1153 [Fuser Cleaning]
001 Compulsion execution - Execute the fusing cleaning mode.
002
Operation interval *ENG
[1 to 300 / 0 / 1 K/step]
Adjusts the execution interval for the fusing cleaning mode.
1K= 100 sheets
003
Control Temp. *ENG
[0 to 200 / 180 / 1°C/step]
Specifies the heating roller temperature for the fusing cleaning mode.
004
Page Count *ENG [1 to 300000 / - / 1 page/step]
Displays the page counter for the fusing cleaning mode.
1801
[Motor Speed Adj.] FA
001 Registration:Plain:Low *ENG
[–2 to 2 / –1.1 / 0.1 %/step]
002 Registration:Plain:High *ENG
[–2 to 2 / –0.1 / 0.1 %/step]
003 Registration:Middle Thick:Low *ENG
[–2 to 2 / –1.1 / 0.1 %/step]
004 Registration:Middle Thick:Mid *ENG
[–2 to 2 / –0.1 / 0.1 %/step]
005 Registration:Middle Thick:High *ENG
006 Registration:Thick 1:Low *ENG
[–2 to 2 / –1.1 / 0.1 %/step]
007 Registration:Thick1:Mid *ENG
[–2 to 2 / –0.1 / 0.1 %/step]
008 Registration:Thick 2:Low *ENG
[–2 to 2 / –1.1 / 0.1 %/step]
009 Registration:Thick 3:Low *ENG
010 Duplex CW:Plane:Low *ENG
[–4 to 4 / 0.0 / 0.1 %/step]
011 Duplex CW:Normal:High *ENG