System SP2-xxx
D086/D087 3-44 SM Appendix
2010
[Charge AC Current: MH] Charge Roller AC Current Adjustment for MH
(Color)
Displays/sets the AC current target of the charge roller for MH environment
(Middle temperature and High humidity). DFU
001 Environmental Target: Bk *ENG
[0 to 3 / 0.74 / 0.01 mA/step]
002 Environmental Target: M *ENG
[0 to 3 / 0.89 / 0.01 mA/step]
003 Environmental Target: C *ENG
004 Environmental Target: Y *ENG
2011
[Charge AC Current: HH] Charge Roller AC Current Adjustment for HH
(Color)
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity). DFU
001 Environmental Target: Bk *ENG
[0 to 3 / 0.74 / 0.01 mA/step]
002 Environmental Target: M *ENG
[0 to 3 / 0.87 / 0.01 mA/step]
003 Environmental Target: C *ENG
004 Environmental Target: Y *ENG
2012 [Charge Output Control]
001 AC Voltage *ENG
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)