System SP2-xxx
SM Appendix 3-45 D086/D087
Appendix:
SP Mode
Tables
2013 [Environmental Correction: PCU]
001
Current Environmental:
Display
*ENG
Displays the environmental condition,
which is measured in absolute humidity.
[1 to 5 / – / 1 /step]
1: LL (LL <= 4.3 g/m
3
)
2: ML (4.3 < ML <= 11.3 g/m
3
)
3: MM (11.3 < MM <= 18.0 g/m
3
)
4: MH (18.0 < MH <= 24.0 g/m
3
)
5: HH (24.0 g/m
3
< HH)
002 Forced Setting *ENG
Selects the environmental condition
manually.
[0 to 5 / 0 / 1 /step]
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
003
Absolute Humidity:
Threshold 1
*ENG
Changes the humidity threshold
between LL and ML.
[0 to 100 / 3.0 / 0.01 g/m
3
/step]
004
Absolute Humidity:
Threshold 2
*ENG
Changes the humidity threshold
between ML and MM.
[0 to 100 / 8.0 / 0.01 g/m
3
/step]
005
Absolute Humidity:
Threshold 3
*ENG
Changes the humidity threshold
between MM and MH.
[0 to 100 / 15.0 / 0.01 g/m
3
/step]
006
Absolute Humidity:
Threshold 4
*ENG
Changes the humidity threshold
between MH and HH.
[0 to 100 / 15.0 / 0.01 g/m
3
/step]
007 Current Temp.: Display *ENG
Displays the current temperature.
[0 to 100 / 0 / 1 deg/step]
008
Current Relative
Humidity: Display
*ENG
Displays the current relative humidity.
[0 to 100 / 0 / 1%RH/step]
009 Current Absolute *ENG Displays the absolute humidity.