Error Codes
D393 30 SM
Code Meaning Suggested Cause/Action
This does not result in an error
communication.
0-88
The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.
2-11
Only one V.21 connection
flag was received
Replace the FCU.
2-12 Modem clock irregularity Replace the FCU.
2-13 Modem initialization error
Turn off the machine, then turn it back on.
Update the modem ROM.
Replace the FCU.
2-23
JBIG compression or
reconstruction error
Turn off the machine, then turn it back on.
2-24 JBIG ASIC error Turn off the machine, then turn it back on.
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
2-27
JBIG data reconstruction
error (End marker error)
2-28
JBIG data reconstruction
error (Timeout)
JBIG data error
Check the sender’s JBIG function.
Update the MBU ROM.
2-29
JBIG trailing edge maker
error
FCU defective
Check the destination device.
2-50
The machine resets itself
for a fatal FCU system
If this is frequent, update the ROM, or replace
the FCU.