Bit Switches
SM 69 D393
Fax Option
Type C5000
(D393)
(8): Total number of burst error lines that occurred during non-ECM reception.
EQM and rx level are fixed at “FFFF” in tx mode.
The seventh and eighth numbers are fixed at “00” for transmission records
and ECM reception records.
Rx level calculation
Example: 0000 // 32 V34 // 288/264 // L 01 00 03 04
The four-digit hexadecimal value (N) after “L” indicates the rx level.
The high byte is given first, followed by the low byte. Divide the decimal value of N
by -16 to get the rx level.
In the above example, the decimal value of N (= 0100 [H]) is 256.
So, the actual rx level is 256/-16 = -16 dB
3
Not used
Do not change this setting.
4
Line error mark print
0: OFF, 1: ON (print)
When "1" is selected, a line error mark is printed
on the printout if a line error occurs during
reception.
5
G3/G4 communication
parameter display
0: Disabled
1: Enabled
This is a fault-finding aid. The LCD shows the key
parameters (see below). This is normally disabled
because it cancels the CSI display for the user.
Be sure to reset this bit to 0 after testing.
6
Protocol dump list output after
each communication
0: Off
1: On
This is only used for communication
troubleshooting. It shows the content of the
transmitted facsimile protocol signals. Always
reset this bit to 0 after finishing testing.
If system switch 09 bit 6 is at “1”, the list is only
printed if there was an error during the
communication.
7 Not used Do not change the setting.
System Switch 01 - Not used (Do not change the factory settings.)