Bit Switches
D393 70 SM
System Switch 02 [SP No. 1-101-003]
No FUNCTION COMMENTS
0-1
Not used
Do not change these settings.
2
Force after transmission stall
0: Off
1: On
With this setting on, the machine resets itself
automatically if a transmission stalls and fails to
complete the job.
3
Not used
Do not change these settings.
4
File retention time
0: Depends on User
Parameter 24 [18(H)]
1: No limit (until the year 2126)
1: A file that had a communication error will not be
erased unless the communication is successful.
5
Not used
Do not change this setting.
6-7
Memory read/write by RDS
Bit 7: 0, Bit 6: 0
Always disabled
Bit 7: 0, Bit 6: 1
User selectable
Bit 7: 1, Bit 6: 0
User selectable
Bit 7: 1, Bit 6: 1
Always enabled
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked
out, but the user can temporarily switch RDS on to
allow RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03. Note
that if an RDS operation takes place, RDS will not
switch off until this time limit has expired.
(1,1): At any time, an RDS system can access the
machine.
System Switch 03 [SP No. 1-101-004]
No FUNCTION COMMENTS
0-7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System
Switch 02 are set to “User selectable”.