Bit Switches
D545 70 SM
System Switch 01 - Not used (Do not change the factory settings.)
System Switch 02 (SP No. 1-101-003)
No Function Comments
0 Not used Do not change these settings.
2
Forced reset after transmission
stalls
0: Off
1: On
With this setting on, the machine resets itself
automatically if a transmission stalls and fails to
complete the job.
3 Not used Do not change these settings.
4
File retention time
0: Depends on User Parameter
24 [18(H)]
1: No limit
1: A file that had a communication error will not
be erased unless the communication is
successful.
5 Not used Do not change this setting.
6-7
Memory read/write by RDS (0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked
out, but the user can temporarily switch RDS
on to allow RDS operations to take place. RDS
will automatically be locked out again after a
certain time, which is stored in System Switch
03. Note that if an RDS operation takes place,
RDS will not switch off until this time limit has
expired.
(1,1): At any time, an RDS system can access
the machine.
Bit 7 Bit 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled