Main SP Tables-1
SM 5-13 D086/D087
System
Maintenance
1102
[Feed Permit Setting]
Specified the settings of the paper feeding timing.
001
Temp.:Lower
Delta:Center
*ENG
[0 to 200 / 15 / 1 deg/step]
002 Temp.:Lower Delta:End *ENG
[0 to 200 / 100 / 1 deg/step]
003
Temp.:Upper
Delta:Center
*ENG
[0 to 200 / 100 / 1 deg/step]
004 Temp.:Upper Delta:End *ENG
[0 to 200 / 100 / 1 deg/step]
005 Temp.:Lower Delta:Press *ENG
[0 to 200 / 100 / 1 deg/step]
006 Rotation Time *ENG
[0 to 100 / 0 / 1 sec/step]
007
Temp.:Lower
Delta:Center:Sp.1
*ENG
[0 to 200 / 5 / 1 deg/step]
008
Temp.:Lower
Delta:End:Sp.1
*ENG
[0 to 200 / 100 / 1 deg/step]
009
Temp.:Upper
Delta:Center:Sp.1
*ENG
[0 to 200 / 100 / 1 deg/step]
010
Temp.:Upper
Delta:End:Sp.1
*ENG
[0 to 200 / 100 / 1 deg/step]
011
Temp.:Lower
Delta:Press:Sp.1
*ENG
[0 to 200 / 60 / 1 deg/step]
012 Rotation Time:Sp.1 *ENG
[0 to 200 / 0 / 1 sec/step]
013
Temp.:Lower
Delta:Center:Sp.2
*ENG
[0 to 200 / 5 / 1 deg/step]
014
Temp.:Lower
Delta:End:Sp.2
*ENG
[0 to 200 / 100 / 1 deg/step]
015
Temp.:Upper
Delta:Center:Sp.2
*ENG
[0 to 200 / 15 / 1 deg/step]