Main SP Tables-1
SM 5-19 D086/D087
System
Maintenance
133
Envelop:Center:Low
Speed
*ENG
[120 to 200 / 170 / 1 deg/step]
134
Envelop:Press:Low
Speed
*ENG
[100 to 200 / 120 / 1 deg/step]
135
Thin:FC:Center:Low
Speed
*ENG
[120 to 200 / 135 / 1 deg/step]
136
Thin:FC:Press:Low
Speed
*ENG
[100 to 200 / 120 / 1 deg/step]
137
Thin:BW:Center:Low
Speed
*ENG
[120 to 200 / 130 / 1 deg/step]
138
Thin:BW:Press:Low
Speed
*ENG
[100 to 200 / 120 / 1 deg/step]
139 Thick4:FC:Center *ENG
[120 to 200 / 175 / 1 deg/step]
140 Thick4:FC:Press *ENG
[100 to 200 / 120 / 1 deg/step]
141 Thick4:BW:Center *ENG
[120 to 200 / 165 / 1 deg/step]
142 Thick4:BW:Press *ENG
[100 to 200 / 120 / 1 deg/step]
1106 [Fusing Temp. Display]
001 Center - [-10 to 250 / - / 1 deg/step]
Displays the temperature of the heating
roller.
002 End -
003 Pressure - [-10 to 250 / - / 1 deg/step]
Displays the temperature of the heating
roller.
004 Pressure End -