Main SP Tables-1
D086/D087 5-20 SM
1107 [Standby Target Temp. Setting]
001
Standby Heater Off Time *ENG
[0 to 100 / 15 / 1 sec/step]
Specifies the time that the fusing heater turns off after the fusing unit
temperature has reached its target temperature.
002
Stanby/Preheat1: Press *ENG
[0 to 125 / 90 / 1 deg/step]
Specifies the temperature of the pressure roller for the ready or energy save 1
mode.
004
Preheat2:Press *ENG
[0 to 125 / 90 / 1 deg/step]
Specifies the temperature of the pressure roller for the energy save 2 mode.
006
Low Power:Press *ENG
[0 to 125 / 60 / 1 deg/step]
Specifies the temperature of the pressure roller for the low power mode.
007
Print Ready:Center *ENG
[120 to 180 / 150 / 1 deg/step]
Specifies the temperature of the heating roller for the print ready condition.
008
Print Ready:Press *ENG
[100 to 200 / 120 / 1 deg/step]
Specifies the temperature of the pressure roller for the print ready condition.
1108 [After Reload/Job Target Temp.]
001
Center *ENG
[120 to 180 / 150 / 1 deg/step]
Specifies the temperature of the heating roller after re-load or job.
002
Press *ENG
[100 to 200 / 120 / 1 deg/step]
Specifies the temperature of the pressure roller after re-load or job.