Main SP Tables-1
SM 5-21 D086/D087
System
Maintenance
1111 [Environment Correction:Fusing]
001
Temp.: Threshold: Low *ENG
[0 to 100 / 17 / 1 deg/step]
Specifies the threshold temperature for low temperature. If the fusing
temperature is 17°C or less, the machine executes the fusing mode for low
temperature.
002
Temp.: Threshold: High *ENG
[0 to 100 / 30 / 1 deg/step]
Sepcifies the threshold temperature for high temperature. If the fusing
temperature is 30°C or more, the machine executes the fusing mode for high
temperature.
003
Low Temp. Correction *ENG
[0 to 15 / 5 / 1 deg/step]
Specifies the additional temperature for the target temperature. If the fusing
temperature is in low temperature condition, this temperature is added to the
taraget temperature.
004
High Temp. Correction *ENG
[0 to 15 / 0 / 1 deg/step]
Specifies the additional temperature for the target temperature. If the fusing
temperature is in high temperature condition, this temperature is added to the
taraget temperature.
005
Job Low Temp.
Correction
*ENG
[0 to 100 / 5 / 0.1 deg/step]
006
Job High Temp.
Correction
*ENG
[0 to 100 / 0 / 0.1 deg/step]
007
Job Low Temp.
Correction:Sp.
*ENG
[0 to 100 / 10 / 0.1 deg/step]
008
Job High Temp.
Correction:Sp.
*ENG
[0 to 100 / 0 / 0.1 deg/step]