Main SP Tables-1
D086/D087 5-22 SM
1113 [Curl Correction]
001
Execute Pattern *ENG
[0 to 2 / 0 / 1 /step]
0: Off, 1: On (No Decurl), 2: On
Selects the curl correction type.
002
Humidity:Threshold:M-humid *ENG
[0 to 100 / 1 / 1 %/step]
Specifies the threshold between low and middle humidity.
003
Humidity:Threshold:H-humid *ENG
[0 to 100 / 65 / 1 %/step]
Specifies the threshold between middle and high humidity.
004
Permit
Temp.:Delta:Press:M-humid
*ENG
[0 to 200 / 60 / 1 deg/step]
Specifies the threshold temperature for the curl control in middle humidity.
005
Permit
Temp.:Delta:Press:H-humid
*ENG
[0 to 200 / 50 / 1 deg/step]
Specifies the threshold temperature for the curl control in high humidity.
006
Permit
Temp.:Delta:Press:M-humid:No
Decurl
*ENG
[0 to 200 / 50 / 1 deg/step]
Specifies the threshold temperature for the no curl control in middle humidity.
007
Permit
Temp.:Delta:Press:H-humid:No
Decurl
*ENG
[0 to 200 / 40 / 1 deg/step]
Specifies the threshold temperature for the no curl control in high humidity.