Main SP Tables-1
SM 5-23 D086/D087
System
Maintenance
008
CPM:M-humid *ENG
[0 to 100 / 80 / 1 %/step]
Specifies the CPM ratio of the decurl control against to the normal operation in
middle humidity.
009
CPM:H-humid *ENG
[0 to 100 / 65 / 1 %/step]
Specifies the CPM ratio of the decurl control against to the normal operation in high
humidity.
010
CPM:M-humid:No Decurl *ENG
[0 to 100 / 80 / 1 %/step]
Specifies the CPM ratio against of the no decurl control to the normal operation in
middle humidity.
011
CPM:H-humid:No Decurl *ENG
[0 to 100 / 65 / 1 %/step]
Specifies the CPM ratio against of the no decurl control to the normal operation in
high humidity.
1115 [Target Temp. Correction]
001
Temp.:Delta:End *ENG
[-100 to 100 / 0 / 1 deg/step]
Specifies the different temperature between end and center of the heating
roller.
1124
[CPM Down Setting]
Specifies the settings for the CPM down mode.
001 Low:Down Temp. *ENG
[-50 to 0 / -20 / 1 deg/step]
Specifies the CPM down threshold temperature for the low temperature
condition. If the fusing temperature decreases -20°C (adjustable) below the
target temperature, the machine enters the CPM down mode.
002 Low:Up Temp. *ENG
[-50 to 0 / -15 / 1 deg/step]
Specifies the CPM up threshold temperature for the low temperature condition.
If the fusing temperature increases -15°C (adjustable) below the target
temperature, the machine enters the CPM up mode.