Main SP Tables-1
SM 5-27 D086/D087
System
Maintenance
1141 [Fusing SC Issue Time Info]
001 SC Number *ENG Displays the issued SC number.
002 SC Cause *ENG
[0 to 9 / - / 1/step]
101 Htg Roller:Ctr Diff1 *ENG
[0 to 260 / - / 1 deg/step]
Displays the temperature at the
center of the heating roller when an
SC was issued.
102 Htg Rolloer:Ctr Det1 *ENG
103 Htg Roller:Ctr Corr1 *ENG
104 Htg Roller:End Diff1 *ENG
[0 to 260 / - / 1 deg/step]
Displays the temperature at the
end of the heating roller when an
SC was issued.
105 Htg Roller:End Det1 *ENG
106 Htg Roller:End Corr1 *ENG
107 Press Roller Temp Value1 *ENG
[0 to 260 / - / 1 deg/step]
Displays the temperature at the
pressure roller when an SC was
issued.
151 Htg Roller:Ctr Diff2 *ENG
[0 to 260 / - / 1 deg/step]
152 Htg Rolloer:Ctr Det2 *ENG
153 Htg Roller:Ctr Corr2 *ENG
154 Htg Roller:End Diff2 *ENG
[0 to 260 / - / 1 deg/step]
155 Htg Roller:End Det2 *ENG
156 Htg Roller:End Corr2 *ENG
157 Press Roller Temp Value2 *ENG [0 to 260 / - / 1 deg/step]
201 Htg Roller:Ctr Diff3 *ENG
[0 to 260 / - / 1 deg/step]
202 Htg Rolloer:Ctr Det3 *ENG
203 Htg Roller:Ctr Corr3 *ENG