Main SP Tables-1
D086/D087 5-28 SM
204 Htg Roller:End Diff3 *ENG
[0 to 260 / - / 1 deg/step]
205 Htg Roller:End Det3 *ENG
206 Htg Roller:End Corr3 *ENG
207 Press Roller Temp Value3 *ENG [0 to 260 / - / 1 deg/step]
1142 [Fusing Jam Detection]
001
SC Display *ENG
[0 or 1 / 0 / -]
Enables or disables the fusing consecutive jam (three times) SC detection.
0: No detection, 1: Detection
1151 [Pressure Setting]
001
Pressure Change ON/OFF *ENG
[0 or 1 / 1 / -]
Enables or disables the pressure switching control for the fusing unit.
0: OFF , 1: ON
002
Pressure Position1 *ENG
[0 to 10,000 / 420 / 10 msec/step]
Specifies the rotation time of the pressure roller contact motor for the pressure
position 1.
003
Pressure Position2 *ENG
[0 to 10,000 / 660 / 10 msec/step]
Specifies the rotation time of the pressure roller contact motor for the pressure
position 2.
004
Pressure Position3 *ENG
[0 to 10,000 / 2130 / 10 msec/step]
Specifies the rotation time of the pressure roller contact motor for the pressure
position 3.