Main SP Tables-2
SM 5-69 D086/D087
System
Maintenance
2241
[Temperature/Humidity: Display]
Displays the environment temperature and humidity.
001 Temperature - [–1280 to 1270 / - / 0.1deg/step]
002 Relative Humidity - [0 to 1000 / - / 0.1 %RH/step]
003 Absolute Humidity - [0 to 100 / - / 0.01 g/m
3
/step]
2302
[Environmental Correction: Transfer]
Environmental Correction: Image Transfer Belt Unit
001
Current Environmental
Display
- Displays the current environment condition.
002 Forced Setting *ENG
Sets the environment condition manually.
[0 to 6 / 0 / 1 /step]
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle
humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
003
Absolute Humidity:
Threshold 1
*ENG
Adjusts the threshold value between LL and
ML.
[0 to 100 / 4 / 0.01 g/m
3
/step]
004
Absolute Humidity:
Threshold 2
*ENG
Adjusts the threshold value between ML
and MM.
[0 to 100 / 8 / 0.01 g/m
3
/step]