Main SP Tables-2
SM 5-97 D086/D087
System
Maintenance
2611
[OHP: Paper Size Correction]
Adjusts the size correction coefficient for the paper transfer roller current for
each paper size. SP2603 and SP2608 are multiplied by these SP values.
001 Paper Transfer: S1 *ENG
[100 to 600 / 100 / 5%/step]
S1 size > 297 mm (Paper width)
002 Paper Transfer: S2 *ENG
[100 to 600 / 140 / 5%/step]
297 mm > S2 size > 275 mm (Paper width)
003 Paper Transfer: S3 *ENG
[100 to 600 / 200 / 5%/step]
275 mm > S3 size > 210 mm (Paper width)
004 Paper Transfer: S4 *ENG
[100 to 600 / 260 / 5%/step]
210 mm > S4 size > 148 mm (Paper width)
005 Paper Transfer: S5 *ENG
[100 to 600 / 330 / 5%/step]
148 mm > S5 size (Paper width)
2621
[OHP: Leadin Edge Correction] OHP: Leading Edge Correction
Adjusts the correction to the paper transfer roller current at the paper leading
edge in each mode. SP2603 and SP2608 are multiplied by these SP values.
The paper leading edge area can be adjusted with SP2622.
001 Paper Transfer *ENG
[0 to 400 / 100 / 5%/step]
2621
Adjusts the correction to the discharge plate current at the paper leading edge
in each mode. SP2601 is multiplied by these SP values.
The paper leading edge area can be adjusted with SP2622.
002 Separation DC *ENG