Main SP Tables-3
D086/D087 5-126 SM
5.4 MAIN SP TABLES-3
5.4.1 SP3-XXX (PROCESS)
3011 [Process Cont. Manual Execution]
001 Normal -
Executes the normal process control
manually (potential control).
Check the result with SP3-325-001 and
3-012-001 after executing this SP.
002 Density Adjustment -
Executes the toner density adjustment
manually.
003 Pre-ACC -
Executes the process control that is
normally done before ACC.
The type of process control is selected with
SP3-041-004.
004 Full MUSIC -
Executes the process control that is
normally done at the same time as MUSIC.
This SP does the MUSIC (line position
adjustment) twice.
005 Normal MUSIC -
Executes the process control that is
normally done at the same time as MUSIC.
This SP does the MUSIC (line position
adjustment) once.