Main SP Tables-3
SM 5-127 D086/D087
System
Maintenance
3012
[Process Cont. Check Result] Process Control Self-check Result
Displays the result of the latest process control self-check.
All colors are displayed. The results are displayed in the order “Y C M K”
e.g., 11 (Y) 99 (C) 11 (M) 11 (K): The self-check for Cyan failed but the others
were successful.
See the "Error Condition Tables" in the "Appendix: Process Control Error
Conditions" section for details.
001 History: Latest *ENG
[1111 to 99999999 / 99999999 / 1/step]
002 Result: Latest 1 *ENG
003 Result: Latest 2 *ENG
004 Result: Latest 3 *ENG
005 Result: Latest 4 *ENG
006 Result: Latest 5 *ENG
007 Result: Latest 6 *ENG
008 Result: Latest 7 *ENG
009 Result: Latest 8 *ENG
010 Result: Latest 9 *ENG
3013 [T Sensor Initial Set: Execution] Developer Initialization Setting
001 Execution: ALL -
Executes the developer initialization for
each color.
002 Execution: COL -
003 Execution: Bk -
004 Execution: M -
005 Execution: C -
006 Execution: Y -