Main SP Tables-3
D086/D087 5-130 SM
3043 [TD Adjustment Mode]
001
Repeat Number: Power ON *ENG
[0 to 9 / 4 / 1 time/step]
Specifies the maximum number of repeats of the toner density adjustment at
power on.
0: Disabled, 1 to 3: Repeat number,
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
002
Repeat Number: Initialization *ENG
[0 to 9 / 3 / 1 time/step]
Specifies the maximum number of repeats of the toner density adjustment at
the developer initialization.
0: Disabled, 1 to 3: Repeat number,
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
003
Repeat Number: Non-use *ENG
[0 to 9 / 0 / 1 time/step]
Specifies the maximum number of repeats of the toner density adjustment in
stand by mode.
0: Disabled, 1 to 3: Repeat number,
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled