Loading...
System SP1-xxx
SM Appendix 3-5 D086/D087
Appendix:
SP Mode
Tables
009
Temp.:Delta:Warm:End *ENG
[40 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the heating roller (end) when the fusing unit
is determined as warm state.
010
Temp.:Delta:Warm:Press *ENG
[0 to 200 / 65 / 1 deg/step]
Specifies the temperature correction of the pressure roller when the fusing unit is
determined as warm state.
011
Time:Warm *ENG
[0 to 100 / 30 / 1 sec/step]
Specifies the threshold time for the fusing reload when the fusing unit is determined
as warm state.
012
Temp.:Delta:Hot:Center *ENG
[0 to 200 / 5 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) when the fusing
unit is determined as hot state.
013
Temp.:Delta:Hot:End *ENG
[40 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the heating roller (end) when the fusing unit
is determined as hot state.
014
Temp.:Delta:Hot:Press *ENG
[0 to 200 / 65 / 1 deg/step]
Specifies the temperature correction of the pressure roller when the fusing unit is
determined as hot state.
015
Time:Hot *ENG
[0 to 100 / 30 / 1 sec/step]
Specifies the threshold time for the fusing reload when the fusing unit is determined
as hot state.
016
Temp.:Delta:Cold:BW:Center *ENG
[0 to 200 / 15 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) in the black and
white mode when the fusing unit is determined as cold state.