EasyManua.ls Logo

Ricoh Aficio MP C3501

Ricoh Aficio MP C3501
1989 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System SP1-xxx
D086/D087 3-4 SM Appendix
1101
[Reload Permit Setting]
Specifies the settings of the reload permit for cold temperature in color mode.
001
Pre-rotation Start Temp. *ENG
[0 to 200 / 0 / 1 deg/step]
Specifies the pre-rotation start temperature.
002
Reload Target Temp.:Center *ENG
[120 to 180 / 150 / 1 deg/step]
Specifies the reload target temperature of the heating roller.
003
Reload Target Temp.:Press *ENG
[0 to 200 / 120 / 1 deg/step]
Specifies the reload target temperature of the pressure roller.
004
Temp.:Delta:Cold:Center *ENG
[0 to 200 / 5 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) when the fusing
unit is determined as cold state.
005
Temp.:Delta:Cold:End *ENG
[40 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the heating roller (end) when the fusing unit
is determined as cold state.
006
Temp.:Delta:Cold:Press *ENG
[0 to 200 / 65 / 1 deg/step]
Specifies the temperature correction of the pressure roller when the fusing unit is
determined as cold state.
007
Time:Cold *ENG
[0 to 100 / 30 / 1 sec/step]
Specifies the threshold time for the fusiing reload when the fusing unit is
determined as cold state.
008
Temp.:Delta:Warm:Center *ENG
[0 to 200 / 5 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) when the fusing
unit is determined as warm state.