System SP1-xxx
D086/D087 3-16 SM Appendix
Correction:Sp.
008
Job High Temp.
Correction:Sp.
*ENG
[0 to 100 / 0 / 0.1 deg/step]
1112 [Repeat Temperature Correction]
001
Control Time 1 *ENG
[0 to 300 / 100 / 1 sec/step]
Specifies the threshold time for entering the repeat temperature correction
mode after the first sheet of paper has reached to the registration roller.
002
Control Time 2 *ENG
[0 to 300 / 300 / 1 sec/step]
Specifies the threshold time for entering the repeat temperature correction
mode after the control time 1 (specified with SP1112-001) has elapsed.
003
Temp.:Plain:Center:1 *ENG
[-15 to 15 / 0 / 0.1 deg/step]
Specifies the correction temperature of the heating roller for plain paper when
the operation time of the machine is in the interval between control time 1 and
control time 2.
004
Temp.:Plain:Press:1 *ENG
[-10 to 10 / 0 / 0.1 deg/step]
Specifies the correction temperature of the pressure roller for plain paper when
the operation time of the machine is in the interval between control time 1 and
control time 2.
005
Temp.:Plain:Center:2 *ENG
[-15 to 15 / -5 / 0.1 deg/step]
Specifies the correction temperature of the heating roller for plain paper when
the operation time of the machine is more than control time 2.
006
Temp.:Plain:Press:2 *ENG
[-10 to 10 / 0 / 0.1 deg/step]
Specifies the correction temperature of the pressure roller for plain paper when
the operation time of the machine is more than control time 2.