System SP1-xxx
SM Appendix 3-19 D086/D087
Appendix:
SP Mode
Tables
006
Permit
Temp.:Delta:Press:M-humid:No
Decurl
*ENG
[0 to 200 / 50 / 1 deg/step]
Specifies the threshold temperature for the no curl control in middle humidity.
007
Permit
Temp.:Delta:Press:H-humid:No
Decurl
*ENG
[0 to 200 / 40 / 1 deg/step]
Specifies the threshold temperature for the no curl control in high humidity.
008
CPM:M-humid *ENG
[0 to 100 / 80 / 1 %/step]
Specifies the CPM ratio of the decurl control against to the normal operation in
middle humidity.
009
CPM:H-humid *ENG
[0 to 100 / 65 / 1 %/step]
Specifies the CPM ratio of the decurl control against to the normal operation in high
humidity.
010
CPM:M-humid:No Decurl *ENG
[0 to 100 / 80 / 1 %/step]
Specifies the CPM ratio against of the no decurl control to the normal operation in
middle humidity.
011
CPM:H-humid:No Decurl *ENG
[0 to 100 / 65 / 1 %/step]
Specifies the CPM ratio against of the no decurl control to the normal operation in
high humidity.