Remote control commandsMXO 4 Series
824User Manual 1335.5337.02 ─ 07
Usage: Query only
Asynchronous command
SBUS<sb>:SPMI:FRAMe<fr>:FLD<fl>:LABel?
Returns the label of the fields in the specified frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
<fl> index of the field
Return values:
<Label>
Usage: Query only
Asynchronous command
SBUS<sb>:SPMI:FRAMe<fr>:FLD<fl>:STATe?
Returns the overall state of the frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
<fl> index of the field
Return values:
<State> OK | NOReponse | ACKerror | BPERror | PARerror | LENerror |
ARBerror | SSCerror | CMDerror | CODerror | INComplete
*RST: OK
Usage: Query only
Asynchronous command
SBUS<sb>:SPMI:FRAMe<fr>:FLD<fl>:VALue?
Returns the data value of the specified field.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
<fl> index of the field
Return values:
<Value> Range: 0 to 18446744073709551615
Increment: 1
*RST: 0