396User Manual 1335.5337.02 ─ 07
Remote command:
SBUS<sb>:LIN:DATA:THReshold on page 796
SBUS<sb>:LIN:DATA:HYSTeresis on page 796
Show threshold lines
If enabled, the threshold lines are displayed in the diagram.
The label of the threshold line is set according to the signal that it is referring to, see
also Show threshold lines.
Remote command:
SBUS<m>:THReshold on page 705
13.6.1.3 Display settings
For details about the display settings, see Chapter 13.1.4, "Display", on page 315.
13.6.2 LIN trigger settings
Access: [Apps] > "Protocol" > "LIN" > "Shortcuts" > "Setup trigger".
Type
Selects the trigger type for LIN analysis.
Some trigger types have additional settings that can be defined. In this case, the "Set
details" button appears next to "Type" the function. Open it for a detailed definition of
the trigger conditions.
"Start of frame
(Sync)"
Triggers on the stop bit of the sync field.
LIN (option R&S MXO4-K520)