Remote control commandsMXO 4 Series
546User Manual 1335.5337.02 ─ 07
Manual operation: See "Filter, Cut-off" on page 149
TRIGger:ANEDge:CUToff:HIGHpass <CutOffFreq>
Frequencies below the cutoff frequency are rejected, higher frequencies pass the filter.
Parameters:
<CutOffFreq> KHZ5 | KHZ50
KHZ5 = 5 kHz
KHZ50 = 50 kHz
*RST: KHZ50
Usage: Asynchronous command
Manual operation: See "Filter, Cut-off" on page 149
TRIGger:ANEDge:CUToff:LOWPass
<CutOffFreq>
Frequencies higher than the cutoff frequency are rejected, lower frequencies pass the
filter.
Parameters:
<CutOffFreq> KHZ50 | MHZ50
KHZ50 = 50 kHz
MHZ50 = 50 MHz
*RST: KHZ50
Usage: Asynchronous command
Manual operation: See "Filter, Cut-off" on page 149
TRIGger:ANEDge:NREJect <NoiseReject>
Enables an automatic hysteresis on the trigger level to avoid unwanted trigger events
caused by noise.
Parameters:
<NoiseReject> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "Trigger noise reject" on page 149
17.9.4 Glitch trigger
TRIGger:EVENt<ev>:GLITch:POLarity............................................................................. 547
TRIGger:EVENt<ev>:GLITch:RANGe...............................................................................547
TRIGger:EVENt<ev>:GLITch:WIDTh................................................................................547
Trigger