Remote control commandsMXO 4 Series
509User Manual 1335.5337.02 ─ 07
Return values:
<State> ON | OFF
*RST: OFF
Usage: Query only
Asynchronous command
Manual operation: See "Mode" on page 108
17.8.4 Vertical setup
The channel suffix <ch> selects the input channel that is affected by the command.
CHANnel<ch>:STATe..................................................................................................... 509
CHANnel<ch>:SCALe.................................................................................................... 509
CHANnel<ch>:RANGe................................................................................................... 510
CHANnel<ch>:OFFSet................................................................................................... 510
CHANnel<ch>:POSition..................................................................................................510
CHANnel<ch>:COUPling.................................................................................................511
CHANnel<ch>:INVert......................................................................................................511
DISPlay:SIGNal:LABel....................................................................................................512
CHANnel<ch>:SKEW:TIME.............................................................................................512
CHANnel<ch>:BANDwidth.............................................................................................. 512
CHANnel<ch>:EATScale................................................................................................ 513
CHANnel<ch>:EATTenuation...........................................................................................513
CHANnel<ch>:IMPedance.............................................................................................. 514
CHANnel<ch>:STATe <State>
Switches the selected channel signal on or off.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "[C<n>]" on page 42
CHANnel<ch>:SCALe <Scale>
Sets the vertical scale, which defines the displayed amplitude of the selected wave-
form.
Suffix:
<ch>
.
1 to 4, index of the analog channel