EasyManua.ls Logo

Rohde & Schwarz MXO 4 Series - Edge Trigger on External Trigger Source

Rohde & Schwarz MXO 4 Series
925 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TriggerMXO 4 Series
147User Manual 1335.5337.02 ─ 07
Level
See "Level" on page 143.
Remote command:
TRIGger:EVENt<ev>:LEVel<n>[:VALue] on page 541
Slope
Sets the edge direction for the trigger.
"Positive"
Selects the rising edge, which is a positive voltage change.
"Negative"
Selects the falling edge, which is a negative voltage change.
"Either"
Selects the rising and falling edge. After starting an acquisition, the
instrument triggers on the first identified edge.
Remote command:
TRIGger:EVENt<ev>:EDGE:SLOPe on page 544
7.4.2 Edge trigger on external trigger source
Access: "Menu" > "Trigger" > "Setup" tab > "Source" = "Extern" > "Type = Analog
Edge"
If an external trigger signal is connected to the Trigger In connector, and the trigger
source is set to "Extern", the analog edge trigger is available. Triggering on an external
source is only possible if you trigger on a single event but not for sequences.
This section describes the trigger-type specific settings. For settings that apply to all
trigger types, see Chapter 7.2, "Common trigger settings", on page 142.
Trigger types

Table of Contents