Remote control commandsMXO 4 Series
485User Manual 1335.5337.02 ─ 07
SYSTem:DISPlay:MESSage[:TEXT] <DisplayMessage>
Defines an additional text that is displayed during remote control operation.
To enable the text display, use SYSTem:DISPlay:MESSage:STATe.
Parameters:
<DisplayMessage>
Usage: Asynchronous command
17.7 Instrument setup
System.................................................................................................................. 485
SmartGrid..............................................................................................................487
Toolbar.................................................................................................................. 492
Appearance...........................................................................................................493
Display.................................................................................................................. 498
Maintenance..........................................................................................................503
17.7.1 System
SYSTem:COMMunicate:NET[:HOSTname].......................................................................485
SYSTem:DATE.............................................................................................................. 485
SYSTem:EXIT................................................................................................................486
SYSTem:FW:FILepath.................................................................................................... 486
SYSTem:PRESet........................................................................................................... 486
SYSTem:SHUTdown...................................................................................................... 486
SYSTem:FW:STARt........................................................................................................487
SYSTem:TIME............................................................................................................... 487
SYSTem:COMMunicate:NET[:HOSTname] <Hostname>
Sets the host name of the instrument, which is required when configuring a network.
After changing the host name, you have to reboot the instrument.
The query SYSTem:COMMunicate:NET:HOSTname? returns the currently defined
host name.
Parameters:
<Hostname> String parameter
Usage: Asynchronous command
Manual operation: See "Device name" on page 76
SYSTem:DATE <Year>,<Month>,<Day>
Sets the date of the internal calendar.