Remote control commandsMXO 4 Series
796User Manual 1335.5337.02 ─ 07
SBUS<sb>:LIN:BITRate <Bitrate>
Sets the number of transmitted bits per second. The maximum bit rate for LIN is 20
kbit/s.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Bitrate> Range: 1000 to 20000000
Increment: 1
*RST: 9600
Default unit: bps
Usage: Asynchronous command
Manual operation: See "Bit rate" on page 395
SBUS<sb>:LIN:DATA:HYSTeresis <Hysteresis>
Sets a value for the hysteresis for the data channel.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Hysteresis>
Usage: Asynchronous command
Manual operation: See "Threshold" on page 395
SBUS<sb>:LIN:DATA:SOURce <DataSource>
Sets the waveform of the data line.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<DataSource> C1 | C2 | C3 | C4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9
| D10 | D11 | D12 | D13 | D14 | D15 | M1 | M2 | M3 | M4 | M5 |
R1 | R2 | R3 | R4
Usage: Asynchronous command
Manual operation: See "Data" on page 394
SBUS<sb>:LIN:DATA:THReshold <Threshold>
Sets a user-defined threshold value for the data channel.
Suffix:
<sb>
.
1...4, index of the serial bus