Remote control commandsMXO 4 Series
836User Manual 1335.5337.02 ─ 07
Return values:
<Count>
Usage: Query only
Asynchronous command
SBUS<sb>:TNOS:FRAMe<fr>:BCOunt?
Returns the number of bytes in the specified frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<Count>
Usage: Query only
Asynchronous command
SBUS<sb>:TNOS:FRAMe<fr>:BITRate?
Returns the primary bit rate.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
Return values:
<PrimaryBitRate> Range: 0 to 100000000000
Increment: 1
*RST: 0
Default unit: bps
Usage: Query only
Asynchronous command
SBUS<sb>:TNOS:FRAMe<fr>:BYTE<o>:COUNt?
Returns the number of bytes in the specified frame.
Suffix:
<sb>
.
1...4, index of the serial bus
<fr> index of the frame
<o> index of the byte
Return values:
<Count>
Usage: Query only
Asynchronous command