Remote Control Commands
R&S
®
SMU200A
557Operating Manual 1007.9845.32 ─ 15
OUTP:PON OFF
RF output A is deactivated when the instrument is switched on.
Example:
:OUTPut:USER<ch>:SOURce <Source>
The command selects the signal for the specified USER interface.
Some signals which can be applied at the USER interface are permanently assigned and
some are assigned using a dedicated command (e.g. OUTP:CW:SOURce for the CW
control signal).
An example of permanently assigned signal is the LEV-ATT control signal of Path B.
The general purpose input (GPINput) is available for USER interfaces 1 and 2 only.
Parameters:
AMARk4|BMARk4|ACW|BCW|ABLank|BBLank|AHOP|BHOP|
BBITclock|BSYMbolclock|BATTenuator|BBURst|ATRig|BTRig|
GPINput
USER1 = AMARker4; USER 2 = ACW; USER 3 =
ABLank; USER 4 = ATRig
<Source>
*RST:
OUTP:USER2 AMAR
causes the marker signal to be output at the USER2 pin of the AUX
I/O interface.
OUTP:CLOC:MODE SYMB
specifies that the internally generated clock pulse is a symbol clock
pulse.
OUTP:CLOC:STAT ON
activates output of the symbol clock pulse at the USER2 pin
Example:
7.14 SENSe, READ and INITiate Subsystems
The SENSe subsystem contains the commands for configuring the power measurements
with power sensor(s) connected to the generator. The measurement is started and the
measurement result retrieved with the READ command. The description of this commands
is included in the following.
Up to three sensors can be connected to the signal generator. They are distinguished by
means of the suffix under SENSe:
●
Power sensor connected to the SENSOR port = SENSe[1]
●
First Power sensor connected to one of the USB interfaces = SENSe 2
●
Second Power sensor connected to one of the USB interfaces = SENSe 3
INITiate<ch>[:POWer]:CONTinuous.................................................................................558
READ<ch>[:POWer].......................................................................................................558
SENSe<ch>[:POWer]:CORRection:SPDevice:STATe........................................................559
SENSe<ch>[:POWer]:DISPlay:PERManent:STATe...........................................................559
SENSe, READ and INITiate Subsystems