Remote Control Commands
R&S
®
SMU200A
760Operating Manual 1007.9845.32 ─ 15
MOD:STAT OFF
switches off all modulations.
Example:
7.15.14 SOURce:PATH Subsystem
This subsystem contains the command for retrieving the number of installed RF paths.
[:SOURce]:PATH:COUNt?
The command queries the number of installed RF paths.
Return values:
integer<Count>
PATH:COUN?
queries the number of RF paths.
Response: 1
the instrument is equipped with one RF path.
Example:
Query onlyUsage:
7.15.15 SOURce:PHASe Subsystem
This subsystem contains the commands for adjusting the phase of the RF output signal
relative to a reference signal of the same frequency.
[:SOURce<hw>]:PHASe.................................................................................................760
[:SOURce<hw>]:PHASe:REFerence................................................................................761
[:SOURce<hw>]:PHASe <Phase>
The command specifies the phase variation relative to the current phase. The variation
can be specified in RADians.
Parameters:
float
-359.9 to 359.9
0.1 deg
0.0 deg
RAD
<Phase>
Range:
Increment:
*RST:
Default unit:
PHAS 2DEG
changes the phase by 2 degrees relative to the current phase.
PHAS:REF
adopts the set phase as the current phase.
Example:
SCPI conformUsage:
SOURce Subsystem